Electrical service wires overhanging a pool, spa, or hot tub must be at least 22 1/2 feet above the surface of the water or surface of the diving platform.Buried wiring runs that transition from underground to above ground must be protected in conduit from the required cover depth or 18 inches (whichever is less) to its termination point above ground, or at least 8 feet above grade.Low-voltage wiring (carrying no more than 30 volts) must be buried at least 6 inches deep.Backfill surrounding conduit or cables must be smooth granular material without rocks.Wiring buried inside rigid metal (RMC) or intermediate metal (IMC) conduit must have at least 6 inches of earth cover wiring in PVC conduit must have at least 18 inches of cover.UF cable can be direct-buried (without conduit) with a minimum of 24 inches of earth cover.Type UF cable is the most commonly used nonmetallic cable for residential outdoor wiring runs. Exposed or buried wiring/cable must be listed for its application.These receptacles must be single receptacles that serve no other devices or appliances. Receptacles used to power pump systems on pools and spas must be no closer than 10 feet from the inside walls of a permanent pool, spa, or hot tub if they are not-GFCI protected, and no closer than 6 feet from the inside walls of a permanent pool or spa if they are GFCI protected.This receptacle must have GFCI protection. The receptacle must be no higher than 6 1/2 feet above the pool deck. A permanent swimming pool must have access to an electrical receptacle that is no closer than 6 feet and no further than 20 feet from the closest edge of the pool.This cover provides sealed weather protection even when cords are plugged into the receptacle. Receptacles in wet locations (exposed to weather) must be weather-resistant and have a weatherproof "in-use" cover.Receptacles in damp locations (under protective covers, such as a porch roof) must be weather-resistant and have a weatherproof (weathertight) cover.As a general recommendation, houses also should have a receptacle at each side of a deck or balcony, accessible from the ground. Benefits & News All products are manufactured in the USA in advanced facilities Centralized stocking in the USA 100 tested Elastimold’s brand’s long, innovative history includes pioneering such products as extended, repair, and jacket seal elbows Elastimold’s accessories, available from 5-138 kV, are used to connect, ground, splice, terminate, and protect underground cable Products. Attached decks and balconies with interior access (including a door to the indoors) must have a receptacle no more than 6 1/2 feet above the deck or balcony walking surface.They must be readily accessible from the ground and positioned no more than 6 1/2 feet above grade (ground level). Homes must have at least one outdoor receptacle at the front and rear of the house.The required GFCI protection can be provided by GFCI receptacles or GFCI circuit breakers.

Specific exceptions may be made for snow-melting or deicing equipment, where the equipment is powered by an inaccessible outlet. GFCI (ground-fault circuit-interrupter) protection is required for all outdoor receptacles.